Power Dynamics, Inc.

    Features
  • General purpose filter with IEC Connector providing effective equipment protection of line-to-ground noise up to 10 Amp., 250 VAC
  • Low cost
  • Compact design
  • Low leakage current: less than 0.5mA max
  • Solder terminals
    Applications
  • Digital electronic equipment, measuring and control equipment, small electronic equipment and pheripherals, ect.
PA01S
PA03S
PA06S
PA10S

Approvals:

Specifications
Model No. PA01S PA03S PA06S PA10S
Rated Voltage 250V AC 250V AC 250V AC 250V AC
Rated Current 1A 3A 6A 10A
Leakage Current 0.5mA MAX
250V, 60Hz
0.5mA MAX
250V, 60Hz
0.5mA MAX
250V, 60Hz
0.5mA MAX
250V, 60Hz
Test
Voltage
Line to Line 1450V DC 1450V DC 1450V DC 1450V DC
Line to Ground 2250V DC 2250V DC 2250V DC 2250V DC
Insulation Resistance 6000M ohms
MIN 250V DC
6000M ohms
MIN 250V DC
6000M ohms
MIN 250V DC
6000M ohms
MIN 250V DC
Direct Current
Resistance
0.5 ohm MAX 0.2 ohm MAX 0.15 ohm MAX 0.1 ohm MAX
Temperature Rise 30°C MAX 30°C MAX 30°C MAX 30°C MAX
Operating Temperature -25°C to
+85°C
-25°C to
+85°C
-25°C to
+85°C
-25°C to
+85°C
Attenuation
Normal Mode
25db MIN
0.60 - 45 MHz 0.80 - 50 MHz 1.00 - 50 MHz 1.00 - 50 MHz
Common Mode
25db MIN
0.10 - 40 MHz 0.20 - 40 MHz 0.50 - 50 MHz 0.70 - 50 MHz

Circuit

Part No. L(mH) x 2 Cx (µF) Cy (pF) x 2
PA01S 3.7 0.1 3300
PA03S 1.8 0.1 3300
PA06S 0.7 0.1 3300
PA10S 0.3 0.1 3300

Drawings


Panel Cut-out

Attenuation in 50 ohm-50 ohm circuit according CISPR
PA01S (1 AMP)

PA03S (3 AMP)

PA06S (6 AMP)

PA10S (10 AMP)

Specifications subject to change without notice. Dimensions in inches. (Metric dimensions are shown in parentheses.)