Beckwith Electronics

Hamburg, Illinois 62045
(618) 232-1139

(618) 232-1172 fax

Contact Us

Power Dynamics, Inc.

    Features
  • General purpose filter with IEC Connector providing effective line-to-ground noise up to 10 amp., 250 VAC.
  • Low cost
  • Compact design
  • Low leakage current: less than 0.5mA max
  • .250" Quick Connect terminals
    Applications
  • Digital electronic equipment, measuring and control equipment, small electronic equipment and pheripherals, ect.
  • Where space is at a premium and a small filter package is required
PA01F
PA03F
PA06F
PA10F

Approvals:

Specifications
Model No. PA01F PA03F PA06F PA10F
Rated Voltage 250V AC 250V AC 250V AC 250V AC
Rated Current 1A 3A 6A 10A
Leakage Current 0.5mA MAX
250V, 60Hz
0.5mA MAX
250V, 60Hz
0.5mA MAX
250V, 60Hz
0.5mA MAX
250V, 60Hz
Test
Voltage
Line to Line 1450V DC 1450V DC 1450V DC 1450V DC
Line to Ground 2250V DC 2250V DC 2250V DC 2250V DC
Insulation Resistance 6000M ohms
MIN 250V DC
6000M ohms
MIN 250V DC
6000M ohms
MIN 250V DC
6000M ohms
MIN 250V DC
Direct Current
Resistance
0.5 ohm MAX 0.2 ohm MAX 0.15 ohm MAX 0.1 ohm MAX
Temperature Rise 30°C MAX 30°C MAX 30°C MAX 30°C MAX
Operating Temperature -25°C to
+85°C
-25°C to
+85°C
-25°C to
+85°C
-25°C to
+85°C
Attenuation
Normal Mode
25db MIN
0.60 - 45 MHz 0.80 - 50 MHz 1.00 - 50 MHz 1.00 - 50 MHz
Common Mode
25db MIN
0.10 - 40 MHz 0.20 - 40 MHz 0.50 - 50 MHz 0.70 - 50 MHz

Circuit

Part No. L(mH) x 2 Cx (µF) Cy (pF) x 2
PA01F 3.7 0.1 3300
PA03F 1.8 0.1 3300
PA06F 0.7 0.1 3300
PA10F 0.3 0.1 3300

Drawings

Attenuation in 50 ohm-50 ohm circuit according CISPR
PA01F (1 AMP)

PA03F (3 AMP)

PA06F (6 AMP)

PA10F (10 AMP)

Specifications subject to change without notice. Dimensions in inches. (Metric dimensions are shown in parentheses.)